Preparation for Use
ADDvantage-32 PLUS AC to DC Power Converter
6-9
TABLE 6-3. RECOMMENDED WIRE SIZES
AC INPUT
(L1,L2,L3)
FIELD
SUPPLY
(L1,L2)
MOTOR
ARMATURE
(A1,A2)
MOTOR
FIELD
(+,-)
CHASSIS GROUND
(ARMATURE BRIDGE)
CHASSIS GROUND
(FIELD SUPPLY)
DRIVE
PART NO.
Recommended
Wire Size*
Recommended
Wire Size**
Recommended
Wire Size*
Recommended
Wire Size**
Bolt
Size***
Recommended
Wire Size
Bolt
Size
Recommended
Wire Size
DC0540
DC0541
DC0542
2 × 300 MCM
2 × 300 MCM
2 × 300 MCM
10 AWG
8 AWG
6 AWG
2 × 500 MCM
2 × 500 MCM
2 × 500 MCM
12 AWG
10 AWG
6 AWG
3/8-16
3/8-16
3/8-16
1/0 AWG
1/0 AWG
1/0 AWG
1/4-20
1/4-20
1/4-20
14 AWG
10 AWG
10 AWG
DC0550
DC0551
DC0552
2 × 350 MCM
2 × 350 MCM
2 × 350 MCM
N. A.
N. A.
N. A.
2 × 500 MCM
2 × 500 MCM
2 × 500 MCM
14 AWG
10 AWG
10 AWG
One ground
connection.
No lugs
required.
1/0 AWG
1/0 AWG
1/0 AWG
N. A.
N. A.
N. A.
N. A.
N. A.
N. A.
DC0850
DC0851
DC0852
3 × 350 MCM
3 × 350 MCM
3 × 350 MCM
10 AWG
8 AWG
6 AWG
3 × 500 MCM
3 × 500 MCM
3 × 500 MCM
12 AWG
10 AWG
6 AWG
3/8-16
3/8-16
3/8-16
2/0 AWG
2/0 AWG
2/0 AWG
1/4-20
1/4-20
1/4-20
14 AWG
10 AWG
10 AWG
DC1550
DC1551
DC1552
5 × 500 MCM
5 × 500 MCM
5 × 500 MCM
10 AWG
8 AWG
6 AWG
6 × 500 MCM
6 × 500 MCM
6 × 500 MCM
12 AWG
10 AWG
6 AWG
3/8-16
3/8-16
3/8-16
4/0 AWG
4/0 AWG
4/0 AWG
1/4-20
1/4-20
1/4-20
14 AWG
10 AWG
10 AWG
DC3000
DC3001
DC3002
****
6 × 1250 MCM
or
8 × 700 MCM
****
6 × 1250 MCM
or
8 × 700 MCM
****
6 × 1250 MCM
or
8 × 700 MCM
10 AWG
8 AWG
6 AWG
****
8 × 1000 MCM
****
8 × 1000 MCM
****
8 × 1000 MCM
12 AWG
10 AWG
6 AWG
1/2-13 × 1.25
1/2-13 × 1.25
1/2-13 × 1.25
400 MCM
400 MCM
400 MCM
1/4-20
1/4-20
1/4-20
14 AWG
10 AWG
10 AWG
* Multiple conductors run in parallel. Lugs are supplied attached to input and output bus bars.
** No lugs are required for these connections. Make connections to TB1 on top of the field supply assembly.
Strip insulation 0.59" from end of wire.
*** Ground lugs are provided attached to these bolts on both sides of the chassis. See outline drawings for
wire size range of these lugs.
**** These units are designed for direct bus bar connection. However, the multiple wire connections indicated
may be used.
Vista de pagina 280
1 2 ... 276 277 278 279 280 281 282 283 284 285 286 ... 465 466

Comentarios a estos manuales

Sin comentarios