Core Software Operation
ADDvantage-32 PLUS AC to DC Power Converter
3-39
6) Enter the correct calibration values for the following parameters:
X***:MFLD %SCALE = ________________
X***:BRIDGE SIZE = ________________
X***:ARM CT OUT = ________________
For AFM applications where the line voltage is above 600V, enter the correct scaling
factors for the voltage sense circuits.
X***:AC VT SCALE = ________________
X***:DC VT SCALE = ________________
7) Configure the drive to have a current reference from a calibration parameter, and
disable the CURRENT LOOP FFWD and SPEED LOOP.
* As an example, in the Speed Loop of 692002.V21 software, the TRQ REF SUM
and D/DT SPD FFWD blocks can be configured to accomplish both tasks:
Figure 3-4. 692002.V21 Software Block Excerpt
a) To configure the drive to have a current reference from a calibration
parameter, (for this example), set P142:ALT TRQ EN = D086:ONE BIT.
The desired armature current value can be obtained by entering the value
into the calibration parameter C037:ALT TRQ STP.
Document Actual Calibration Parameter Used
C____:________________ = 0
b) To disable the CURRENT LOOP FFWD (for this example), set the D/DT
SPD FFWD gain to zero. C035: SPD FFWD GN = 0
c) To disable the SPEED LOOP (for this example), set the BIT2 of the TRQ
REF summing block, parameter P141:SPD LP EN, to D087:ZERO BIT.