Maintenance and Troubleshooting
ADDvantage-32 PLUS ● AC to DC Power Converter
7-8
TABLE 7-2. POWERUP MESSAGES (cont.)
FAULT MESSAGE PROBLEM SOLUTION
-------WARNING-------
CONFIG P/N DOES NOT
MATCH HARDWARE ID
UP key to continue
The drive part number
in DRIVE CONFIG
(Y000: DRIVE PN) is
incorrect for the drive
hardware.
a. Insure that Y000 is correct and
matches the part number of the
drive.
b. Replace the microprocessor board
c. Replace the bridge interface board.
d. Replace the ribbon cable between
the microprocessor board and the
bridge interface board
-------WARNING-------
FAILURE TO TRANSFER
CAL and CONFIG
cycle power to reset
Failure to transfer
necessary calibration
and configuration data
between processors
a. Cycle power to the drive.
b. Replace microprocessor board.
-------STATUS-------
ATTEMPTING
TO LOCK THE PLL
TO THE AC LINE
Status message
indicating drive has not
been able to synchronize
to the AC line.
If good AC power is applied to the
drive and the status message persists:
a. Replace the microprocessor board
b. Replace the bridge interface board
c. Replace the ribbon cable between
the bridge interface and
microprocessor boards.
By holding down the UP, DOWN,
LEFT and RIGHT keys at the same
time, the drive will bypass the PLL
LOCK. The drive will not gate any
SCR’s while in the bypass mode.
-------STATUS-------
ATTEMPTING TO
BRING UP THE FIELD
Status message
indicating that the drive
is starting the field.
Status indication only
-------WARNING-------
USB INITIALIZATION
FAILED
UP key to continue
Drive unable to
initialize the USB
subsystem.
a. Cycle power to drive
b. Replace microprocessor board
Note that by pressing the UP key the
drive will complete initialization. No
USB functions will be successful if the
initialization failed.
Comentarios a estos manuales