IEEE 802.3 Ethernet Communication
ADDvantage-32 PLUS
8-8
ETHERNET. You will not be able to download Calibration and Configuration data to the drive
via ADDAPT 2000 over ETHERNET until these parameters are correctly set.
Obtain unused IP addresses from your MIS or IT department when setting up drives on a
network so the ID jumper may be set accordingly (or set ADDR LO to the available last octet).
If you are unsure if an IP Address is already used, use the “PING” command at a DOS prompt
on a PC connected on the network. The PING” command can be used to test the
communication between the PC and another network device over the network. To invoke the
PING command, go to a DOS prompt and type “ping xxx.xxx.xxx.yyy”, where xxx.xxx.xxx is
the 1
st
three octets of the other device’s IP address and yyy is the number you picked. If you
receive Request Timeouts, there is nothing currently on the network using that address.
However, if the drives are connected to your company’s network, and you don’t obtain an
address from your MIS Department, there could be a device that is currently off that could be
turned on at a later time resulting in problems. The following illustrates a return following a
PING command:
C:\>ping 10.1.207.213
Pinging 10 1.207.213 with 32 bytes of data:
Reply from 10.1.207.213: bytes=32 time<10ms TTL=128
Reply from 10.1.207.213: bytes=32 time<10ms TTL=128
Reply from 10.1.207.213: bytes=32 time<10ms TTL=128
Reply from 10.1.207.213: bytes=32 time<10ms TTL=128
Ping statistics for 10.1.207.213:
Packets: Sent = 4, Received = 4, Lost = 0 (0% loss),
Approximate round trip times in milliseconds:
Minimum = 0ms, Maximum = 0ms, Average = 0ms
“Request timed out” indicates the device is not present or not communicating.
“Destination host unreachable” indicates you are not on the correct network or are not
connected.
There are ESBX Ethernet configuration parameters contained in “DRIVE CALIBRATE”(X)
and “DRIVE CONFIGURE” (Y) menus of the ADDvantage-32 PLUS Drive. The parameter
numbers will vary depending on the ADDvantage-32 PLUS Application software being used
and will be noted below as “***”. Please reference Appendix C of your ADDvantage-32 PLUS
Drive manual that shows the parameter listing for your application software.
Drive Calibrate Menu – “X” Parameters