Introduction and General Information
ADDvantage-32 PLUS ● AC to DC Power Converter
1-2
● Tach loss and overspeed protection, configurable with automatic switchover to a
redundant digital tach or armature voltage feedback.
● Heat sink overtemperature warning
● DC motor temperature sensing with overtemperature protection
● AC line fuses and a DC link fuse on regenerative units
(DC link fuse is only used on units rated 10 through 510 and 550 ADC)
● Individual semiconductor fuses in each leg of SCR bridge (applies to units rated
at 850A and above)
● Fully rated DC contactor with optional DB pole available
● Chassis type construction
● Instantaneous Over Current (IOC) protection
● Phase loss/Phase sequence protection
● Field current loss protection
● Field economy
● Low AC line voltage and frequency protection
● 16 event Fault FIFO
● All drive information accessible by remote operator interface over a RS485
multidrop link or Ethernet via optional daughter board
● USB interface to allow save/restore calibration data, store signal analyzer data,
and upgrade firmware
● Single PC board controller design
● Terminal block compatible with prior generation Add-32 drive
1.2 HARDWARE AND EQUIPMENT FEATURES
Figures 1-1, 1-2, and 1-3 illustrate the three typical hardware configurations of the
ADDvantage-32 PLUS Power Converters. Each hardware configuration contains a
microprocessor board, bridge interface board, and a power base. Hardware configuration
varies with the output rating of the ADDvantage-32 PLUS being used.
Figure 1-4 shows a typical Advanced Firing Module. The AFM hardware generally
includes the same items listed above except for the power base.
Comentarios a estos manuales