Upgrade to New Control Board
ADDvantage-32 PLUS ● AC to DC Power Converter
12-22
Figure 12-17. This is the dialog box for the Template Open Directory field.
The template files contain information on all of the calibration and configuration data for
a particular part number and version of drive software. Although the template files are
typically used by the ADDAPT program, the ConvertToADD32Plus utility uses
information contained in the template files to evaluate if a particular file conversion may
be performed. The template files for both the ADDvantage-32 drive and the
ADDvantage-32 PLUS must exist in the specified template file directory or the utility
will be unable to perform a file conversion.
If the ADDAPT2000 software has been installed on the computer, the template file
directory will default to the template subdirectory used by ADDAPT2000.
12.2.2.4 THE ADD-32 PLUS CONFIGURATION FILE FIELD
The third field that must be entered specifies the location and name of the file that is
created as a result of the conversion. As with the other two fields, the user may either
type in the path and file name or use the BROWSE button to set the file path and name.
If the user enters the path and name of a file that already exists, the program will generate
a warning when the conversion is initiated, indicating that an existing file will be
overwritten with the new configuration result. The user will then be able to accept or
cancel the conversion. Accepting will cause the file to be overwritten, cancelling will
abort the conversion and allow the user to enter a different and unique file name.