ADDvantage-32 PLUS AC to DC Power Converter
2-14
Pressing the UP or DOWN keys again will scroll through to the MINIMUM VALUE that
the parameter may have as indicated by an “L” (for low limit) replacing the “H”.
Continue pressing the UP or DOWN to scroll through to a “D”, which indicates the
default value of the parameter. The default value is the original value before any edits to
the parameter were made.
In order to perform an edit of the numeric value of the parameter, the left most character
must be the “V”.
When the actual value of the parameter is being displayed, the RIGHT key is used to
move the cursor to the right of the “V” and begin the edit of the actual parameter value.
The blank spaces and digits of the number may be edited.
When the cursor is at the location that is to be changed, pressing the UP or DOWN key
will scroll through the following character list:
BLANK SPACE, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, MINUS, DECIMAL POINT
Once a particular cursor location has been set to the desired value, pressing the RIGHT
key again will move the cursor to the next character to the right. By repeatedly pressing
the RIGHT key, the cursor will move from left to right and then loop back to the far left
of the editable field on the LCD display.
After completing the number change, pressing the ENTER key will then store the value,
assuming that the value displayed is a valid number and lies within the MINIMUM-
MAXIMUM limits of the parameter. Assuming the edited parameter is valid, the
updated value will also be stored into non-volatile memory when the edit is completed.
If the user wishes to discard the edit, the value may be disposed of by pressing the LEFT
key. No change will be made to the parameter in non-volatile memory, and the unedited
value of the parameter will be refreshed on the LCD display.
2.6 CONFIGURATION PARAMETERS
By navigating the ADDvantage-32 PLUS menus and submenus the user will ultimately
be able to locate a drive parameter of interest. The LCD display of the parameter will be
in one of two formats: the format for numeric data such as calibration and real time data,
or the format for configuration data.