TABLE 7-2. POWERUP MESSAGES
FAULT MESSAGE PROBLEM SOLUTION
SOFTWARE LOAD FAIL
invalid APPL SPACE
low level download
required
Microprocessor board
detected invalid or
corrupt drive software.
a. Replace microprocessor board.
HARDWARE LOAD FAIL
fail to ld AT9 FPGA
reset required
Microprocessor unable
to load programming
into a field
programmable gate
array
a. Cycle power to drive
b. Replace microprocessor board
SOFTWARE LOAD FAIL
missing AT9 FPGA IMG
low level download
required
Microprocessor board
detected invalid or
corrupt drive software.
a. Replace microprocessor board
SOFTWARE LOAD FAIL
missing STR FPGA IMG
low level download
required
Microprocessor board
detected invalid or
corrupt drive software.
a. Replace microprocessor board
-------WARNING-------
LOAD FAILURE
STR912 FPGA PROGRAM
cycle power to reset
Microprocessor unable
to load programming
into a field
programmable gate
array
a. Cycle power to drive
b. Replace microprocessor board
LOAD FAILURE
BRG I/F FPGA PROGRAM
cycle power to reset
Microprocessor unable
to load programming
into a field
programmable gate
array
a. Cycle power to drive
b. Replace microprocessor board
B-B Com Timeout
HWR VALID WAIT FAIL
cycle power to reset
Communication failure
between
microprocessors.
a. Cycle power to drive
b. Replace microprocessor board
-------WARNING-------
INVALID APPLICATION
perform DEFAULT?
UP=YES, DOWN=NO
Microprocessor board
detected invalid or
corrupt drive software.
a. Cycle power to drive
b. Press UP key, then reload drive
firmware and calibration data
c. Replace microprocessor board