ADDvantage-32 PLUS AC to DC Power Converter
2-10
The drive core software is responsible for the basic functions of the drive, including
protective functions, control of the SCR firing, reading analog and digital inputs,
generating analog and digital outputs, measuring the tach feedback and communications.
In addition, the drive core software controls the signal analyzer and maintains the drive
table data. Below it can be seen that the X*** and Y*** parameters are associated with
the core software. The X*** calibration parameters define such things as feedback
scaling, analog input scaling, analog output scaling, firing angle limits and tach scaling,
to name a few. The Y*** configuration parameters define such things as the DRIVE
PART NUMBER, bridge self test mode, 2/4 quadrant bridge operation, tach type, sources
for the analog and digital outputs to name a few. All of the T*** table calibration data
and the Z*** signal analyzer calibration and configuration data is also associated with the
core software.
The block software consists of the all of the control blocks required to implement the
control scheme in the drive. The C*** calibration parameters and the P*** configuration
parameters allow the user to customize features and functions of the control blocks to
meet the needs of their unique applications.
2.4 LCD DISPLAY PARAMETER FORMAT
Through navigation of the ADDvantage32 PLUS menus and submenus, the user will
ultimately be able to locate a drive parameter of interest.
2.4.1 CALIBRATION, ANALOG, TABLE PARAMETERS
The LCD display of the parameter will be in one of two formats: the format for numeric
data such as calibration and real time data, or the format for configuration data.
The format for the numeric data is as follows:
1. Parameter Group - Represents the type of data to be edited. (See Table 2-1.)
2. Parameter Number - Each parameter within a data type has a unique parameter
number. (See Appendix A.)
3. Label - Each parameter has a unique 11 character label. (See Appendix B.)