IEEE 802.3 Ethernet Communication
ADDvantage-32 PLUS
8-12
you are attempting to download to a failed Ethernet board whose failure symptom was a total
loss in communication, then the procedure below for downloading ESBX software to the board
will not work as communication with board is required. Avtron’s factory can program the
ESBX board without communication but it is not available for field use at this time.
The IP ADDRESS that should be entered into the ESBX ZAP program is the IP ADDRESS
that is set in the “DRIVE CALIBRATION” menu. The IP ADDRESS is not programmed into
the ESBX board; the ESBX board obtains its IP ADDRESS from the ADDvantage-32 PLUS
drive on which it is mounted. The reason the ESBX ZAP program needs the board’s IP
ADDRESS is because the programming data is sent to the board via ETHERNET and the IP
ADDRESS is the board address.
MAC or Media Access Control address is a unique value associated with a network adapter.
MAC addresses are also known as hardware addresses or physical addresses. The MAC
address remains fixed and follows the network device, but the IP address changes as the
network device moves from one network to another. TCP/IP protocol is a higher level and
requires the IP address.
ESBX Ethernet Board Firmware Download Instructions:
1. Record Target ADDvantage-32 PLUS drive information (Drive IP and Subnet mask
addresses). From the drive keypad, enter the “Drive Calibrate” menu and record the
following parameters: The “X parameter numbers shown below are for drive
application software P/N 694012 V13. Please reference Appendix C of your
ADDvantage-32 PLUS Drive manual that shows the parameter listing for your specific
application software.
X090: IP ADDR HI __________________
X091: IP ADDR HM __________________
X092: IP ADDR LM __________________
X093: IP ADDR LO __________________
X094: MSK ADDR HI __________________
X095: MSK ADDR HM __________________
X096: MSK ADDR LM __________________
X097: MSK ADDR LO __________________
NOTE
Do not enter the number 256 for X093. Use the actual
DRIVE ID jumper settings on J8 as viewed for DRIVE
COM ID in the drive’s Diagnostic menu. If X093 does not
equal 256 then use the number in X093.
2. Record the ESBX board MAC Address, located on label of U1 of the ESBX board.