IEEE 802.3 Ethernet Communication
ADDvantage-32 PLUS
8-25
PPR No Reply: counter containing the number of times the ADD-32 PLUS did not reply to a
PEER PRIMITIVE transaction initiated by the ESBX module. Increments of this counter
indicate that the ADD-32 PLUS may not be responding to the ESBX and may be the result of a
hardware problem or a possible software problem. Contact Engineering if this counter is
incrementing.
QRY Frames: the number of QUERY frames received by the module.
QRY Responses: the number of QUERY RESPONSE frames generated by this drive. Note
that a response will be generated only if a QUERY frame is received and the DRIVE ID and
MACHINE number of the drive fall within the range specified by the QUERY frame.
QRY Overrun: counter containing the number of QUERY frames that were discarded due to
an overflow of the QUERY command queue. Increments of this counter indicate that excessive
volumes of QUERY frames are being received by the ESBX module. This indicates an
application problem.
QRY Send Fail: counter containing the number of failures returned by the QUERY response
socket send operation. Increments of this counter indicate a probable network configuration
problem, most likely related to the drive IP address, subnet mask, or gateway address.
QRY Xmit Fail: counter containing the number of QUERY RESPONSE frame transmit
failures. Increments of this counter could indicate a possible network configuration problem,
(possibly related to the drive IP address, subnet mask, or gateway address) or a software related
problem.
EXCHG Frames: number of EXCHANGE FRAMES received by the drive.
EXCHG Busy: counter containing the number of EXCHANGE commands that were aborted
due to the buffer between the ESBX and the drive being busy. This counter incrementing
indicates a communication error between the ESBX module and the drive and should be
reported to Engineering.
ASCAN Frames: number of EXCHANGE FRAMES received by the drive.
ASCAN Overrun: counter containing the number of ASCAN or EXCHANGE frames that
were discarded due to an overflow of the ASCAN/EXCHANGE command queue. Increments
of this counter indicate that excessive volumes of ASCAN and/or EXCHANGE frames are
being received by the ESBX module. This indicates an application problem.
ASCAN Send Fail: counter containing the number of failures returned by the ASCAN
response socket send operation. Increments of this counter indicate a probable network
configuration problem, most likely related to the drive IP address, subnet mask, or gateway
address.